EEPs

EnOcean Equipment Profiles

# EEP Description
1A5-02-01Temp. Sensor -40°C to 0°C
2A5-02-02Temp. Sensor -30°C to +10°C
3A5-02-03Temp. Sensor -20°C to +20°C
4A5-02-04Temp. Sensor -10°C to +30°C
5A5-02-05Temp. Sensor 0°C to +40°C
6A5-02-06Temp. Sensor +10°C to +50°C
7A5-02-07Temp. Sensor +20°C to +60°C
8A5-02-08Temp. Sensor +30°C to +70°C
9A5-02-09Temp. Sensor +40°C to +80°C
10A5-02-0ATemp. Sensor +50°C to +90°C
11A5-02-0BTemp. Sensor +60°C to +100°C
12A5-02-10Temp. Sensor -60°C to +20°C
13A5-02-11Temp. Sensor -50°C to +30°C
14A5-02-12Temp. Sensor -40°C to +40°C
15A5-02-13Temp. Sensor -30°C to +50°C
16A5-02-14Temp. Sensor -20°C to +60°C
17A5-02-15Temp. Sensor -10°C to +70°C
18A5-02-16Temp. Sensor 0°C to +80°C
19A5-02-17Temp. Sensor +10°C to +90°C
20A5-02-18Temp. Sensor +20°C to +100°C
21A5-02-19Temp. Sensor +30°C to +110°C
22A5-02-1ATemp. Sensor +40°C to +120°C
23A5-02-1BTemp. Sensor +50°C to +130°C
24A5-02-20Temp. Sensor -10°C to +41.2°C
25A5-02-30Temp. Sensor -40°C to +62.3°C
26A5-04-01Temp. 0°C to +40°C, Humidity 0% to 100%
27A5-04-02Temp. -20°C to +60°C, Humidity 0% to 100%
28A5-04-03Temp. -20°C to +60°C, Humidity 10bit 0% to 100%
29A5-04-04Temp -40°C to +120°C 12bit, Humidity 0% to 100%
30A5-05-01Barometric Sensor 500 to 1150 hPa
31A5-06-01Light Sensor 300lx to 60.000lx
32A5-06-02Light Sensor 0lx to 1.020lx
33A5-06-03Light Sensor 10-bit 0lx to 1000lx
34A5-06-04Curtain Wall Brightness Sensor
35A5-06-05Light Sensor 0lx to 10.200lx
36A5-07-01Occupancy, Supply voltage (optional)
37A5-07-02Occupancy, Supply voltage
38A5-07-03Occupancy, Supply voltage, Light Sensor
39A5-08-01Light 0lx to 510lx, Temp. 0°C to +51°C, Occ. Button
40A5-08-02Light 0lx to 1020lx, Temp. 0°C to +51°C, Occ. Button
41A5-08-03Light 0lx to 1530lx, Temp. -30°C to +50°C, Occ. Button
42A5-09-02CO-Sensor 0 ppm to 1020 ppm
43A5-09-04CO2 Sensor
44A5-09-05VOC Sensor
45A5-09-06Radon Sensor
46A5-09-07Particles Sensor
47A5-09-08Pure CO2 Sensor
48A5-09-09Pure CO2 Sensor, Power Failure Detection
49A5-09-0AHydrogen Gas Sensor
50A5-09-0BRadioactivity Sensor
51A5-09-0CVOC Sensor
52A5-10-01Temp. Sensor, Set Point, Fan Speed, Occ. Control
53A5-10-02Temp. Sensor, Set Point, Fan Speed, Day/Night Control
54A5-10-03Temp. Sensor, Set Point Control
55A5-10-04Temp. Sensor, Set Point, Fan Speed Control
56A5-10-05Temp. Sensor, Set Point, Occupancy Control
57A5-10-06Temp. Sensor, Set Point, Day/Night Control
58A5-10-07Temp. Sensor, Fan Speed Control
59A5-10-08Temp. Sensor, Fan Speed, Occupancy Control
60A5-10-09Temp. Sensor, Fan Speed, Day/Night Control
61A5-10-0ATemp. Sensor, Set Point Adjust, Single Input Contact
62A5-10-0BTemp. Sensor, Single Input Contact
63A5-10-0CTemp. Sensor, Occupancy Control
64A5-10-0DTemp. Sensor, Day/Night Control
65A5-10-10Temp. Sensor, Humidity Sensor, Set Point, Occ. Control
66A5-10-11Temp. Sensor, Humidity Sensor, Set Point, Day/Night Control
67A5-10-12Temp. Sensor, Humidity Sensor, Set Point
68A5-10-13Temp. Sensor, Humidity Sensor, Occupancy Control
69A5-10-14Temp. Sensor, Humidity Sensor, Day/Night Control
70A5-10-15Temp. Sensor, Set Point Control
71A5-10-16Temp. Sensor, Set Point Control, Occupancy Control
72A5-10-17Temp. Sensor, Occupancy Control
73A5-10-18Temp. Sensor, Light, Set Point, , Fan Speed, Occ. Ctrl
74A5-10-19Temp. Sensor, Humidity, Set Point, Fan Speed, Occ. Ctrl.
75A5-10-1ATemp. Sensor, Supply voltage, Set Point, Fan Speed, Occ. Ctrl.
76A5-10-1BTemp. Sensor, Supply Voltage, Light, Fan Speed, Occ. Ctrl.
77A5-10-1CTemp. Sensor, Light, Light Set Point, Fan Speed, Occ. Ctrl.
78A5-10-1DTemp. Sensor, Humidity, Hum. Set Point, Fan Speed, Occ. Ctrl.
79A5-10-1ETemp. Sensor, Supply Voltage, Light, Fan Speed, Occ. Ctrl.
80A5-10-1FTemp. Sensor, Set Point, Fan Speed, Occ./Unocc. Ctrl.
81A5-10-20Temp. Sensor, Set Point with Special Heating States
82A5-10-21Temp. Sensor, Humidity, Set Point with Special Heat. States
83A5-10-22Temp. Sensor, Set Point, Humidity, Fan Speed
84A5-10-23Temp. Sensor, Set Point, Humidity, Fan Speed, Occ. Ctrl.
85A5-11-01Lighting Controller Status
86A5-11-02Temperature Controller Output Status
87A5-11-03Blind Status
88A5-11-04Extended Lighting Status
89A5-11-05Dual-Channel Switch Actuator (BI-DIR) Status
90A5-12-00Automated Meter Reading: Counter
91A5-12-01Automated Meter Reading: Electricity
92A5-12-02Automated Meter Reading: Gas
93A5-12-03Automated Meter Reading: Water
94A5-12-04Automated Meter Reading: Temp., Load Sensor
95A5-12-05Automated Meter Reading: Temp., Container Sensor
96A5-12-10Automated Meter Reading: Current meter 16 channels
97A5-13-01Weather Station
98A5-13-02Sun Intensity
99A5-13-03Date Exchange
100A5-13-04Time/Day Exchange
101A5-13-05Direction Exchange
102A5-13-06Geographic Position Exchange
103A5-13-07Wind Sensor
104A5-13-08Rain Sensor
105A5-13-10Sun position/radiation
106A5-14-01Single Inp. Contact (Window/Door), Supply voltage
107A5-14-02Single Inp. Contact (Window/Door), Supply voltage, Light
108A5-14-03Single Inp. Contact (Window/Door), Supply voltage, Vibr.
109A5-14-04Single Inp. Contact (Window/Door), Supply voltage, Vibr., Light
110A5-14-05Vibration/Tilt, Supply voltage
111A5-14-06Vibration/Tilt, Light and Supply voltage
112A5-14-07Dual-door-contact, Supply monitor
113A5-14-08Dual-door-contact, Supply voltage, Vibration
114A5-14-09Window/Door-Contact, Supply voltage
115A5-14-0AWindow/Door-Contact, Supply voltage, Vibration
116A5-20-01Battery Powered HVAC Actuator (BI-DIR)
117A5-20-02HVAC Basic Actuator (BI-DIR)
118A5-20-03Line powered HVAC Actuator (BI-DIR)
119A5-20-04Heat. Rad. Valve Act. Drive, Feed, Temp., Set Point, Displ. (BI-DIR)
120A5-20-05HVAC Ventilation Unit (BI-DIR)
121A5-20-06Harvesting-powered actuator with local temperature offset control (BI-DIR)
122A5-20-10Generic HVAC Interface (BI-DIR)
123A5-20-11Generic HVAC Interface – Error Control (BI-DIR)
124A5-20-12HVAC Temperature Controller Input
125A5-30-01Single Input Contact, Supply voltage
126A5-30-02Single Input Contact
127A5-30-034 Digital Inputs, Wake and Temp. Sensor
128A5-30-043 Digital Inputs, 1 Digital Input 8 Bits
129A5-30-05Single Input Contact, Retransmission, Supply voltage
130A5-37-01Demand Response
131A5-38-08Gateway
132A5-38-09Extended Lighting-Control
133A5-3F-00Radio Link Test (BI-DIR)
134A5-3F-7FUniversal
135D2-00-01RCP: Temp Sensor, Display (BI-DIR)
136D2-01-00Electr. switches/dimmers, Energy Meas. / Local Ctrl. Type 0x00
137D2-01-01Electr. switches/dimmers, Energy Meas. / Local Ctrl. Type 0x01
138D2-01-02Electr. switches/dimmers, Energy Meas. / Local Ctrl. Type 0x02
139D2-01-03Electr. switches/dimmers, Energy Meas. / Local Ctrl. Type 0x03
140D2-01-04Electr. switches/dimmers, Energy Meas. / Local Ctrl. Type 0x04
141D2-01-05Electr. switches/dimmers, Energy Meas. / Local Ctrl. Type 0x05
142D2-01-06Electr. switches/dimmers, Energy Meas. / Local Ctrl. Type 0x06
143D2-01-07Electr. switches/dimmers, Energy Meas. / Local Ctrl. Type 0x07
144D2-01-08Electr. switches/dimmers, Energy Meas. / Local Ctrl. Type 0x08
145D2-01-09Electr. switches/dimmers, Energy Meas. / Local Ctrl. Type 0x09
146D2-01-0AElectr. switches/dimmers, Energy Meas. / Local Ctrl. Type 0x0A
147D2-01-0BElectr. switches/dimmers, Energy Meas. / Local Ctrl. Type 0x0B
148D2-01-0CElectr. switches/dimmers, Energy Meas. / Local Ctrl. Type 0x0C
149D2-01-0DElectr. switches/dimmers, Energy Meas. / Local Ctrl. Type 0x0D
150D2-01-0EElectr. switches/dimmers, Energy Meas. / Local Ctrl. Type 0x0E
151D2-01-0FElectr. switches/dimmers, Energy Meas. / Local Ctrl. Type 0x0F
152D2-01-10Electr. switches/dimmers, Energy Meas. / Local Ctrl. Type 0x10
153D2-01-11Electr. switches/dimmers, Energy Meas. / Local Ctrl. Type 0x11
154D2-01-12Electr. switches/dimmers, Energy Meas. / Local Ctrl. Type 0x12
155D2-01-13Electr. switches/dimmers, Energy Meas. / Local Ctrl. Type 0x13
156D2-01-14Electr. switches/dimmers, Energy Meas. / Local Ctrl. Type 0x14
157D2-02-00Temp. Sensor, Light, Occupancy, SmokeType 0x00
158D2-02-01Temp. Sensor, Light, Occupancy, SmokeType 0x01
159D2-02-02Temp. Sensor, Light, Occupancy, SmokeType 0x02
160D2-03-00Light, Switching and Blind Control Type 0x00
161D2-03-0APush Button – Single Button
162D2-03-10Mechanical Handle
163D2-03-20Beacon with Vibration Detection
164D2-04-00Temp. Sensor, CO2, Humidity, Day/Night, Autonomy Type 0x00
165D2-04-01Temp. Sensor, CO2, Humidity, Day/Night, Autonomy Type 0x01
166D2-04-02Temp. Sensor, CO2, Humidity, Day/Night, Autonomy Type 0x02
167D2-04-03Temp. Sensor, CO2, Humidity, Day/Night, Autonomy Type 0x03
168D2-04-04Temp. Sensor, CO2, Humidity, Day/Night, Autonomy Type 0x04
169D2-04-05Temp. Sensor, CO2, Humidity, Day/Night, Autonomy Type 0x05
170D2-04-06Temp. Sensor, CO2, Humidity, Day/Night, Autonomy Type 0x06
171D2-04-07Temp. Sensor, CO2, Humidity, Day/Night, Autonomy Type 0x07
172D2-04-08Temp. Sensor, CO2, Humidity, Day/Night, Autonomy Type 0x08
173D2-04-09Temp. Sensor, CO2, Humidity, Day/Night, Autonomy Type 0x09
174D2-04-10Temp. Sensor, CO2, Humidity, Day/Night, Autonomy Type 0x10
175D2-04-1ATemp. Sensor, CO2, Humidity, Day/Night, Autonomy Type 0x1A
176D2-04-1BTemp. Sensor, CO2, Humidity, Day/Night, Autonomy Type 0x1B
177D2-04-1CTemp. Sensor, CO2, Humidity, Day/Night, Autonomy Type 0x1C
178D2-04-1DTemp. Sensor, CO2, Humidity, Day/Night, Autonomy Type 0x1D
179D2-04-1ETemp. Sensor, CO2, Humidity, Day/Night, Autonomy Type 0x1E
180D2-05 BliBlinds Control for Position/Angle
181D2-05-00Blinds Control for Position/Angle Type 0x00
182D2-05-01Blinds Control for Position/Angle Type 0x01
183D2-05-02Blinds Control for Position/Angle Type 0x02
184D2-06-01Window Handly Alarm, Position, Vacation Mode, Optional Sensors
185D2-10-00RCP: Temp., Fan Speed Ctrl., Room Status Info, Time Prg. Type 0x00
186D2-10-01RCP: Temp., Fan Speed Ctrl., Room Status Info, Time Prg. Type 0x01
187D2-10-02RCP: Temp., Fan Speed Ctrl., Room Status Info, Time Prg. Type 0x02
188D2-11-01Room Operating Panel (BI-DIR) Type 0x01
189D2-11-02Room Operating Panel (BI-DIR) Type 0x02
190D2-11-03Room Operating Panel (BI-DIR) Type 0x03
191D2-11-04Room Operating Panel (BI-DIR) Type 0x04
192D2-11-05Room Operating Panel (BI-DIR) Type 0x05
193D2-11-06Room Operating Panel (BI-DIR) Type 0x06
194D2-11-07Room Operating Panel (BI-DIR) Type 0x07
195D2-11-08Room Operating Panel (BI-DIR) Type 0x08
196D2-14-30Sensor for Smoke, Air quality, Hygrothermal comfort, Temperature and Humidity
197D2-20-00Fan Control Type 0x00
198D2-20-01Fan Control Type 0x01
199D2-20-02Fan Control Type 0x02
200D2-30-00Floor Heating Ctrls/Autom. Meter Reading Type 0x00
201D2-30-01Floor Heating Ctrls/Autom. Meter Reading Type 0x01
202D2-30-02Floor Heating Ctrls/Autom. Meter Reading Type 0x02
203D2-30-03Floor Heating Ctrls/Autom. Meter Reading Type 0x03
204D2-30-04Floor Heating Ctrls/Autom. Meter Reading Type 0x04
205D2-30-05Floor Heating Ctrls/Autom. Meter Reading Type 0x05
206D2-30-06Floor Heating Ctrls/Autom. Meter Reading Type 0x06
207D2-31-00Autom. Meter Reading Gateway Type 0x00
208D2-31-01Autom. Meter Reading Gateway Type 0x01
209D2-32-00A.C. Current Clamp Type 0x00
210D2-32-01A.C. Current Clamp Type 0x01
211D2-32-02A.C. Current Clamp Type 0x02
212D2-33-00Intelligent Heaters and Controllers (BI-DIR) Type 0x00
213D2-40-00LED Controller Status Type 0x00
214D2-40-01LED Controller Status Type 0x01
215D2-50-00Heat Recovery Ventilation Type 0x00
216D2-50-01Heat Recovery Ventilation Type 0x01
217D2-A0-01Valve Control (BI-DIR)
218D2-B0-51Liquid leakage sensor Mechanic Harvester
219D2-B1-00Level sensor - Dispenser
220D5-00-01Single Input Contact
221F6-01-01Push Button
222F6-02-01Light and Blind Control - App. Style 1
223F6-02-02Light and Blind Control - App. Style 2
224F6-02-03Light Control - App. Style 1
225F6-02-04Light and blind control ERP2
226F6-03-01Light and Blind Control - App. Style 1
227F6-03-02Light and Blind Control - App. Style 2
228F6-04-01Key Card Activated Switch
229F6-04-02Key Card Activated Switch ERP2
230F6-05-00Wind Speed Threshold Detector
231F6-05-01Liquid Leakage Sensor (mech. harvester)
232F6-05-02Smoke Detector
233F6-10-00Window Handle
234F6-10-01Window Handle ERP2
235Generic ProfileGeneric Profile